| Place of Origin: | China |
| Brand Name: | Labtech |
| Model Number: | M500T |
| Certification: | CE |
| Minimum Order Quantity: | 1 |
| Price: | $1399 |
| Packaging Details: | 39X35X33cm |
| Delivery Time: | 1-2 weeks |
| Payment Terms: | TT in advance |
| Supply Ability: | 100 units/month |
* Color High contrast LCD touchscreen, 7.0 inches.
* Intelligent operation system provides features including user management, calibration management, method management, data
management and etc.
* Multi-reading feature allows auto-read, timed-read and continuous-read.
* Automatic/Manual temperature compensation ensures accurate results.
* Data Storage 1000 sets for each parameter (GLP-compliant).
* Data analysis feature helps user review, compare and recalculate results.
* Support for USB or RS-232 communication.
* Reset feature automatically resumes all settings back to factory default options.
* IP54 waterproof.
pH
* 1-6 points calibration with Standard Recognition.
* Selectable pH buffer groups, including DIN, NIST, USA, MERK, JIS, GB.
* Support for pH standard group customization.
* Automatic electrode diagnosis with pH slope and offset display.
Ion
* 1-6 points calibration
* Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
* Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
* Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc.,
user-defined method is supported.
Conductivity
* 1-5 points calibration with Standard Recognition.
* Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient
and TDS factor.
* Temperature compensation type (none, linear, pure water).
DO
* Support for air-saturated water or zero oxygen calibration.
* Auto barometric pressure compensation.
* Manual Salinity Factor Correction.
* Selectable pressure unit, including kPa, mbar, Torr, Atm.
To measure pH/conductivity/Ion concentration/DO/ Temperature/ TDS/ mV/ORP/ Salinity/Resistivity in pure water,fresh water, waste water, marine water and solutions
| Model | M500T | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001pH | |
| Accuracy | ±0.002 pH | |
| Calibration Points | Up to 6 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV | |
| Accuracy | ±0.1 mV or ±0.03% of reading whichever is greater | |
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1 custom point (relative mV) | |
| pX | Range | -2.000 to 20.000 pX |
| Resolution | 0.1, 0.01, 0.001 pX | |
| Accuracy | ±0.002 pX | |
| Calibration Points | Up to 6 | |
| ISE | Range | 1E-9 to 9.999E9 |
| Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ±0.3% | |
| Calibration Points | Up to 6 | |
| Conductivity | Range | 0.000 μS/cm to 2000 mS/cm |
| Resolution | 0.001 μS/cm minimum, various with range selection | |
| Accuracy | ±0.5% FS | |
| Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
| Calibration Points | Up to 5 | |
| Calibration Reminder | Yes | |
| Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm | |
| Resistivity | Range | 5.00 Ω`cm~100.00 MΩ`cm |
| Resolution | 0.01 Ω`cm minimum | |
| Accuracy | ±0.5% FS | |
| TDS | Range | 0.000~1000 ppt |
| Resolution | 0.001 ppm minimum, changed with range | |
| Accuracy | ±0.5%FS | |
| Salinity | Type | NaCl% |
| Range | (0.00~8.00)% | |
| Resolution | 0.01% | |
| Accuracy | ±0.1% | |
| DissolvedOxygen Concentration - Polarographic | Range | 0.00 to 99.99 mg/L |
| Resolution | 0.01 mg/L | |
| Accuracy | ±0.3mg/L (0.00 to 20.00 mg/L); ±10% (20.00 to 99.99 mg/L) | |
| Calibration Reminder | Yes | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| % Saturation -Polarographic | Range | (0.0 to 600)% |
| Resolution | 0.10% | |
| Accuracy | ±2.0% | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Log Management | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer, scanner, auto-sampler | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Power | AC Adapter, 100-240V AC input, DC24V output |
| Dimensions | 220×195×68 mm | |
| Weight | 950g (2.09 lb) | |